3MRETRACTION PCS
3M ESPE Retraction Pcsdelivers a retraction paste thatcontains 15% aluminum chloride. The astringent retraction paste is placeddirectly into the sulcus via a patented, easy-to-use, hygienic unit-dose Pcs.The Pcs are compatible with most composite dispensers.
INDICATIONS:
3M™ Retraction Pcs is indicated for thetemporary tissue retraction of the marginal gingiva to provide a dry sulcuswhen the periodontium is healthy, such as:
·Takingimpressions (material-based or digital)
·Preparationof temporary casts
·Preparationof Class II and V fillings
Retracts tissue gently
·A greatimpression—even a digital impression—starts with controlling tissue andmoisture. Our Pcs’s extra-fine tip delivers hemostatic paste right into thesulcus to gently retract tissue and control bleeding.
Save time
·Unlikegingival retraction cords that can be difficult and time-consuming to place,the 3M retraction Pcs is a fast, convenient and effective solution for gingivalretraction. With its extra-fine tip, the 3M retraction Pcs delivers a 15%aluminum chloride astringent paste right into the sulcus, pushing the gingivaltissue away from the tooth and allowing you to capture a detailed impression ofthe preparation margin.
FEATURES
- Viscosity:Heavy Body
- The extra fine tip fits directly into the sulcus.
- Enables a clean, dry sulcus and robust hemostasis.
- Hygienic unit-dose Pcs.
- Versus dental retraction cords:
- Convenient and time-saving retraction process: Up to 50% faster.
- Lower risk of hemorrhage.
- Gentle on tissue for improved patient comfort.
- Versus competing pastes:
- Easy access into the sulcus.
- Better interproximal access due to Pcs’s extra-fine tip.
- Compatible with most composite dispensers.
KEY SPECIFICATION
PRECAUTIONS:
The product must not beused in patients suffering from a diseased periodontium, open furcations orexposed bone.
FREQUENTLY ASKED QUESTIONS:
For how long can the pastebe left in the sulcus?
- Typically, the paste should be left in the sulcus for a minimum of 2 minutes to achieve good retraction results. If a hemostatic device is applied too long it may exert unwanted negative effects on the tissue health. Therefore, the hemostatic retraction paste must be rinsed off completely.
How long can one store the Pcsoutside of the blister?
- The Pcs must be taken out of the blister immediately prior to application. It should not be stored outside the blister.
How many teeth can be treatedwith one Pcs?
- The content of one unit-dose Pcs is sufficient to treat up to 3 teeth. The Pcs are for single use and must not be used on more than one patient.
What is the orientationring for?
- The orientation ring corresponds in size and position to the perio probe. It is a feature for more precise and easy intraoral handling.
Why is there a lower riskof bleeding/post-hemorrhage than with cords?
- Cords consist of small fibers that may be incorporated in the coagulum. When the cord is removed, the wound might be opened again. The paste is washed off by air-water spray and suction, resulting in a clean and dry sulcus area.
How can one judge if theretraction effect is sufficient?
- The preparation margin should be clearly visible in the impression. The amount of excessive impression material (“flash”) that covers sulcular areas below the preparation margin is not important.
Does the 3M™ ESPE™Retraction Pcs influence the setting of impression materials?
- As with all astringents, the 3M ESPE astringent retraction paste may inhibit the setting of A-silicones (VPS) and Polyethers. The paste must be completely rinsed off with air-water spray and suction prior to impression taking.
INSTRUCTIONS TO USE:
1) Remove a retraction Pcsfrom the blister and insert into dispenser (fits into most compositedispensers). Extrude a small amount of paste and discard.
2)Insert retraction Pcstip into the sulcus.
3)Slowly andsteadily, inject astringent retraction paste into sulcus. Completely fill thesulcus.
4)OPTIONAL:PROCEDURE WITH CORDS.For more gingival deflection, the astringentretraction paste can be used in combination with retraction cords.
5)Leave astringentretraction paste on for a minimum of 2 minutes.
6) Completely removeastringent retraction paste with air-water spray and suction.
PACKAGING
EXPIRY 2026-08
"Thesale of this item may be subject to regulation by the U.S. Food and DrugAdministration and state and local regulatory agencies. If so, do not offer onthis item unless you are an authorized purchaser. If the item is subject to FDAregulation, I will verify your status as an authorized purchaser of this itembefore shipping of the item."