Bio-Rad iCycler iQ Multicolor Real-Time PCR Detection System — complete three-piece system consisting of the iCycler Thermal Cycler base, the iCycler iQ Optical Module, and the iCycler Optical System Power Supply.
WHAT'S INCLUDED
- Bio-Rad iCycler Thermal Cycler — Serial No. 582BR 011615
- Bio-Rad iCycler iQ Optical Module — Serial No. 584BR 4071
- Bio-Rad iCycler Optical System Power Supply — Model WSX4001
- Power cords and RS-232 interface cable as pictured
TECHNICAL SPECIFICATIONS
Thermal Cycler Base (582BR)
- Peltier-driven heating and cooling system for rapid ramp performance
- 96-well reaction block format, 0.2 mL tubes/plates
- Thermal gradient capability for annealing temperature optimization
- Input: 100–120 / 220–240 VAC, 50–60 Hz
- Max Power: 910 VA
- Fuses: 100–120V T 8A / 220–240V T 4A
- Rear voltage selector currently set to 115V
- Rear DB9 (RS-232) serial port for PC communication
- Front control panel: backlit LCD, alphanumeric keypad, F1–F5 soft keys, ENTER/BACK/STOP, directional pad
- CE marked, EN 61010-1, Made in U.S.A.
iQ Optical Module (584BR)
- Multicolor real-time fluorescence detection module, mounts directly to the thermal cycler base
- Broad-spectrum light source with filter-based optical design allowing selection of optimal excitation and emission wavelengths for discrimination between multiple fluorophores Bio-Rad
- CCD detector with a 350,000 pixel array for simultaneous imaging of all 96 wells Bio-Rad
- Fan-cooled 50-watt tungsten-halogen excitation source
- Compatible with SYBR Green I and standard multiplex fluorophore chemistries
- Made in U.S.A.
Optical System Power Supply (WSX4001)
- Input: 100–250 VAC, 50/60 Hz, 2.5–1.0 A
- Output: 5V @ 3A, 12V @ 5A, −12V @ 250 mA, 24V @ 500 mA
- ON/OFF rocker switch, CE / TÜV certified, Made in U.S.A.
CONDITION
Used, removed from a working laboratory environment. The unit powers on and boots to the Bio-Rad iCycler User Logon screen as shown in the photos. Beyond confirming power-up and display function, no further testing has been performed. No PCR run, thermal calibration, optical calibration, or well-uniformity test has been conducted, and the optical module's lamp and CCD have not been verified.
Cosmetically the system is in good used condition with normal lab wear: light soiling, minor scuffs, and yellowing of the plastic on the power supply housing consistent with age. No cracks or broken housings observed.