Heat.net

Heat.net Store Home


Liebert APM 45K-F 45kVA / 45 kW 208 volt UPS System - UPS and MBP For Sale


Liebert APM 45K-F 45kVA / 45 kW 208 volt UPS System - UPS and MBP
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.

Buy Now

Liebert APM 45K-F 45kVA / 45 kW 208 volt UPS System - UPS and MBP :
$22000.00

HomeAbout UsContact UsPayment & DeliveryReturnsLiebert APM 45K-F 45kVA / 45 kW 208 volt UPS System

Liebert APM 45K-F 45kVA / 45 kW 208 volt UPS System

Battery system sold separately
Liebert APM 45K-F 45kVA / 45 kW 208 volt UPS System will provide redundancy and scalability using innovative Liebert modular power core assemblies. Each includes distributed intelligence and scalable power in one common module. This technology allows configuration of a completely redundant power and control system, sized to match the capacity of the protected equipment. When power requirements change, capacity is easily added – without increasing the system footprint. The Liebert APM UPS scales from 15 to 45kW in a cabinet configuration that includes internal batteries, or from 15 to 90kW in 15kW increments in a configuration that reserves a cabinet for capacity that is paired with an external battery cabinet. This approach allows for right-sizing of the UPS, resulting in improved energy efficiency and reduced power expenditures.Liebert APM 45K-F 4560kVA / 45 kW 208 volt UPS System in stock with a Maintenance bypass / power distribution cabinets and two matching battery cabinets. We can provide the appropriate battery from our large new battery inventory or source any brand battery you prefer. We only provide high rate batteries designed for use in UPS equipment.Liebert APM 45K-F 4560kVA / 45 kW 208volt UPS System Bypass Distribution Cabinet External maintenance bypass provides complete serviceability while load is running on bypass utility power Integral distribution saves space and cost Kirk-key interlock ensures proper operation 65 kAIC rating meets high electrical withstand requirements.
This System can be configured in 15 kva increments to 90 kVA / 90 kW.
Performance Requirements AC Input to UPS
  1. Voltage Configuration for Standard Units: 208V, three-phase, four-wire plus ground
  2. Voltage Range: +15%, -20% of nominal without derating
  3. Frequency: 40-70Hz
  4. Power Factor: 99 full load, 0.98 half load
  5. Inrush Current: UPS inrush current not to exceed 1.5 times rated input current. Maintenance bypass and distribution cabinet inrush current not to exceed 8 times rated input current.
  6. Current Limit: 140% of nominal AC input current maximum
  7. Current Distortion: <3% reflected THD maximum at full load
  8. Surge Protection: Sustains input surges without damage per criteria listed in IEC 1000-4-5
AC Output, UPS Inverter
  1. Voltage Configuration: three-phase, 4-wire plus ground
  2. Voltage Regulation:
±1% three-phase RMS average for a balanced three-phase load for the combined variation effects of input voltage, connected load, battery voltage, ambient temperature and load power factor±5% three-phase RMS average for a 100% unbalanced load for the combined variation effects of input voltage, connected load, battery voltage, ambient temperature and load power factor
  1. Frequency: ±0.1% (single Liebert FlexPower assembly)
±0.25% (six Liebert FlexPower assemblies)
  1. Frequency Slew Rate: Selectable from 0.1Hz/sec to 3.0Hz/sec maximum for single unit
  2. Phase Balance:
120 degrees ±1 degree for balanced load120 degrees ±1.5 degrees for 100% unbalanced load
  1. Voltage Distortion:
<1% total harmonic distortion (THD) for linear loads<5% THD for 100% nonlinear loads (3:1 crest factor) without kVA/kW derating
  1. Load Power Factor Range:7 lagging to 0.9 leading without derating
  2. Output Power Rating:99 full load. 0.98 half load
  3. Overload Capability:
110% for 60 minutes125% for 10 minutes150% for 60 seconds
  1. Voltage Transient Response: 100% load step, ±5.0%
  2. Transient Recovery Time: to within 5% of steady state output voltage within half a cycle
  3. Voltage Unbalance: 100% unbalanced load, ±5%
ENVIRONMENTAL CONDITIONSThe UPS shall be able to withstand the following environmental conditions without damage or degradation of operating characteristics:
  1. Operating Ambient Temperature
UPS Module: 32°F to 104°F (0°C to 40°C)Battery: 77°F ±9°F (25°C ±5°C)
  1. Storage/Transport Ambient Temperature
UPS Module: -4°F to 158°F (-20°C to 70°C)Battery: -4°F to 86°F (-20°C to 30°C)
  1. Relative Humidity
0 to 95%, non-condensing
  1. Altitude
Operating: 3300 ft. (1000m) above sea level; derate power by 1% per 330 ft. (100m) between 3300 and 6000 ft (1000m and 2000m).Storage/Transport: to 40,000 ft. (12,200m) above mean sea level.
  1. Audible Noise
56 dB (45kW/kVA models)60 dB (90kW/kVA models)

  • APC - All
  • APC Symmetra
  • APC Parts
  • UPS Modules
  • UPS Parts

Contact us

Somerset Power Systems
800 E Covey Lane, Suite 140
Phoenix, AZ 85024 - USA

Payment Information

Full payment is required within 3 days of sale close. We accept WireTransfer, VISA, MasterCard, American Express, Discover, Cashiers Check, Commercial Check, and payments by PayPal. Buyer pays shipping charges. Shipping charges are not refundable. Somerset Capital Group dba Somerset Power Systems is required to collect sales tax in every tax district. If you are a reseller, please send in your resale certificate.

Shipping

Please see the Shipping tab to calculate rates.

Return Policy

Within 30 days of placing your order, please contact Somerset Power Systems via your order for a refund. Include photos and a detailed description.

Customer must ship the products to the address mentioned in the return instructions at their own expense. If you would like a pre-paid shipping label, please request one, and we will deduct the shipping cost from your refund. A partial refund may be accepted for items returned used or damaged. No returns will be accepted or refunds issued without requesting a return from . Return instructions must be followed to receive and process your refund or avoid any charges or replacements. Refunds are not accepted for international orders.

About Somerset Power Systems (SPS)

Somerset Power Systems is a division of Somerset Capital Group, LTD. SPS brings together \"old school quality with today\'s technical skills\" We make the buying and owning process as quick, easy and reliable as possible.

Celebrating 32 years in business Somerset Capital Group, LTD is a lessor of refurbished and new data room and other capital equipment including uninterruptible power. Somerset structures both Operating and Capital leases tailored to the equipment and financing needs of our customers.

All of our refurbished UPS Equipment is thoroughly tested and repaired to manufacturer\'s standards.

Have idle, excess, or overstocked power equipment? Somerset is an active buyer for all the types of equipment we sell.

Contact us

Somerset Power Systems
800 E Covey Lane, Suite 140
Phoenix, AZ 85024 - USA


Buy Now

Other Related Items:



Related Items:

Liebert APM 45K-F 45KVA UPS 120/240 NRB40CCSAHA0929 (SKU: 5557AA) picture

Liebert APM 45K-F 45KVA UPS 120/240 NRB40CCSAHA0929 (SKU: 5557AA)

$3850.08



60 KVA UPS - Liebert - Vertiv APM -480-208/208  No batteries- Warranty picture

60 KVA UPS - Liebert - Vertiv APM -480-208/208 No batteries- Warranty

$5795.00



Liebert APM 45K-F 45kVA / 45 kW 208 volt UPS System - UPS and MBP  picture

Liebert APM 45K-F 45kVA / 45 kW 208 volt UPS System - UPS and MBP

$22000.00