12" Patient Monitor ICU CCU Vital Sign For Hospital ECG NIBP RESP TEMP SPO2 PR (SNP900N)
Features:
1. 12.1" TFT color LCD,800*600dpi
2. Standard 6 para: ECG, SpO2, NIBP, TEMP, RESP, PR
3. Fanless design, quiet, energy-saving and clean
4. With the standard interface, OxyCRG, trend chard, big character interface and view bed,
5. Operation mode: keys and buttons.
6. Display up to 8-channel waveform on one screen.
7. NIBP measurement mode: Manual/AUTO/Continuous, storage for 1000-group NlBP data
8. Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
9. AC/DC, built-in rechargeable lithium battery achieves uninterrupted monitoring.
Standard Parameters:
ECG, RESP, TEMP, NIBP, SPO2, PR
Technique Specifications:
ECG
1. Lead Mode: 5 Leads (I, II, III, AVR, AVL, AVF, V)
2. Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
3. Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)
① Resolution: 1 BPM
② Accuracy: ±1%
③ Sensitivity >200 uV(Peak to peak)
4. ST measurement range: -2.0 ~ +2.0 mV
① Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater
Other Range: unspecified
5. Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s
6. Diagnostic: 0.05~130 Hz
7. Monitor: 0.5~40 Hz
8. Surgery: 1~20 Hz
SPO2
1. Measuring Range:35%~100%
2. Resolution: 1%
3. Certainty of measurement: In the range of 70% to 100%, the precision should be ± 3%
4. Pulse Rate: 20-250 BPM
5. Resolution ratio: 1 BPM
6. Accuracy: 2 BPM
NIBP
1. Method: Pulse wave oscillation method
2. Measure mode: Manual / Automatic / Continuous
3. Unit: mmHg, kPa
4. Measure and alarm range:
5.1 Adult Mode
① SYS 30 ~ 255 mmHg
② DIA 10 ~ 220 mmHg
③ MEAN 20 ~ 235 mmHg
5.2 Pediatric Mode
① SYS 30 ~ 255 mmHg
② DIA 10 ~ 220 mmHg
③ MEAN 20 ~ 235 mmHg
5.3 Neonatal Mode
① SYS 30 ~ 135 mmHg
② DIA 10 ~ 110 mmHg
③ MEAN 20 ~ 125 mmHg
6. Resolution ratio: 1mmHg
7. Accuracy: 5mmHg
RESP
1. Method: Impedance between RA-LL or RALA
2. Measurement Range:
① Adult: 0 ~ 120 BrPM
② Neonatal / Pediatric: 0 ~ 150 BrPM
3. Resolution ratio: 1 BrPM
4. Accuracy: 2 BrPM
TEMP
1. Measure and Alarm Range: 0 ~ 50℃
2. Resolution ratio: 0.1℃
3. Certainty of measurement: ± 0.1℃ (without probe error)
Standard Configurations:
Patient Monitor *1
Power Cord *1
Spo2 Sensor *1
Temp Sensor *1
5-lead ECG Cable *1
Electrodes *10
NIBP Cuff *1
NIBP Extension Hose *1
User Manual *1
Ground Line *1 8" Patient Monitor ICU CCU Vital Sign For Hospital NIBP, SPO2, PR,TEMP(PM80B)
Standard Parameters:
NIBP, SPO2, PR,TEMP
Features:
1.Compact and flexible appearance.
2.Simple and convenient operation, which is applicable for community medical treatment and family ect.
3.8 inch high resolution color TFT display.
4.Adjustable audible and visual alarms.
5.Built-in rechargeable lithium battery for uninterrupted monitoring.
Technique Specification:
1.SPO2
①Measuring Range: 0 ~ 100 %
②Resolution: 1%
③Accuracy: 70% ~ 100% (2 %)
④Pulse Rate: 20-250 BPM
⑤Resolution: 1 BPM
⑥Accuracy: 3 BPM
2.NIBP
2.1.Method: Oscillometry
2.2.Measure mode: Manual, Auto, STAT
2.3.Unit: mmHg, kPa
2.4.Measure and alarm range:
2.5.Adult Mode
①SYS 40 ~ 280 mmHg
②DIA 10 ~ 225 mmHg
③MEAN 20 ~ 240 mmHg
2.6.Pediatric Mode
①SYS 40 ~ 220 mmHg
②DIA 10 ~ 160 mmHg
③MEAN 20 ~ 170 mmHg
2.7.Neonatal Mode
①SYS 40 ~ 135 mmHg
②DIA 10 ~ 100 mmHg
③MEAN 20 ~ 110 mmHg
2.8.Resolution: 1mmHg
2.9.Accuracy: 5mmHg
3.TEMP
①Measure and Alarm Range: 0 ~ 50 C
②Resolution: 0.1C
③Accuracy: 0.1C
Standard Configuration:
1.Main Unit *1
2.Adult Spo2 probe *1
3.Adult NIBP cuff *1
4.NIBP extension tube *1
5.Power Cable *1
6.Power adapter *1
7.User Manual *1
8.Temperature probe *1FDAStatement: